GPO number  | 
Output type  | 
STREET  | 
SPORT  | 
V1  | 
RACE  | 
PRO  | 
GPO 1  | 
Low driving (GND), max 2A  | 
yes  | 
yes  | 
yes  | 
yes  | 
yes  | 
GPO 2  | 
Low driving (GND), max 2A  | 
yes  | 
yes  | 
yes  | 
yes  | 
yes  | 
GPO 3  | 
Low driving (GND), max 2A  | 
yes  | 
yes  | 
yes  | 
yes  | 
yes  | 
GPO 4  | 
Low driving (GND), max 2A  | 
yes  | 
yes  | 
yes  | 
yes  | 
|
GPO 5  | 
Low driving (GND), max 2A  | 
yes  | 
yes  | 
yes  | 
yes  | 
|
GPO 6  | 
Low driving (GND), max 2A  | 
yes  | 
yes  | 
yes  | 
||
GPO 7  | 
Low driving (GND), max 2A  | 
yes  | 
yes  | 
yes  | 
||
GPO 8 / TACHO  | 
Low driving (GND), max 5A  | 
yes  | 
yes  | 
yes  | 
yes  | 
yes  | 
GPO 9/WBO heater 1  | 
Low driving (GND), max 2A  | 
yes  | 
yes  | 
yes  | 
yes  | 
yes  | 
GPO 10/WBO heater 2  | 
Low driving (GND), max 2A  | 
yes  | 
||||
GPO 11/Motor 1-  | 
H-bridge, 2A, 5A peak  | 
yes  | 
yes  | 
yes  | 
||
GPO 12/Motor 1+  | 
H-bridge, 2A, 5A peak  | 
yes  | 
yes  | 
yes  | 
||
GPO 13/Motor 2+  | 
H-bridge, 2A, 5A peak  | 
yes  | 
yes  | 
|||
GPO 14/Motor 2-  | 
H-bridge, 2A, 5A peak  | 
yes  | 
yes  | 
|||
GPO 15  | 
High driving (+12V), max 4A  | 
yes  | 
yes  | 
|||
GPO 16  | 
High driving (+12V), max 4A  | 
yes  | 
yes  | 
|||
GPO 17  | 
High driving (+12V), max 4A  | 
yes  | 
||||
GPO 18  | 
High driving (+12V), max 4A  | 
yes  | 
||||
GPO 19  | 
High driving (+12V), max 4A  | 
yes  | 
||||
GPO 20  | 
High driving (+12V), max 4A  | 
yes  | 
||||
GPO 21  | 
High driving (+12V), max 4A  | 
yes  | 
||||
GPO 22  | 
High driving (+12V), max 4A  | 
yes  | 
||||
GPO 23  | 
Low driving (GND), max 1.5A  | 
yes  | 
||||
GPO 24  | 
Low driving (GND), max 1.5A  | 
yes  | 
||||
GPO 25  | 
Low driving (GND), max 1.5A  | 
yes  | 
||||
GPO 26  | 
Low driving (GND), max 1.5A  | 
yes  | 
||||
GPO 27  | 
Low driving (GND), max 1.5A  | 
yes  | 
||||
GPO 28  | 
Low driving (GND), max 1.5A  | 
yes  | 
||||
GPO 29  | 
Low driving (GND), max 1.5A  | 
yes  | 
||||
GPO 30  | 
Low driving (GND), max 1.5A  | 
yes  | 
•When output is off/disabled, the output is grounded.
When output is on/activated, the output is +12V.
Note: H-bridge are useful for driving motors in both directions, otherwise you never use this type of output.
For power hungry E-Throttles (like the BMW S54), it is recommended to paralell wire the outputs, see BMW S54.
•When output is off(disabled, the output is not connected.
•When output is on/activated, the output is grounded.
•When output is off/disabled, the output is not connected.
•When output is on/activated, the output is +12V.
Note: GPO 8 on all ECUs has a 660ohm pullup to either +5V or +12V (selectable in software)
Wiring a LED to a GPO can cause the LED to "always be a bit on" cause of the leak current, by adding a ~120ohm/3W resistor in parallel over the LED will solve the problem.