Note: if you want to trigger a digital input function from an analog input, see Digital inputs.
Note: All analog inputs tolerate up to +12 V, but measurement is limited to 0–5.0 V.
Temperature sensors has two wires and are not polarity sensitive.
•Sensor GND.
•Available AIN (temperature) on MaxxECU.
Note: Internal pullup on MaxxECU AINx (temperature) is 2k5 ohm).
Example temperature wiring to a MaxxECU RACE, see complete PDF wiring diagrams on our download page.
Example MTune setting for a wired analog temperature sensor.
|
0-5v sensors (pressure etc) do have three wires that needs to be connected:
•+5V sensor supply.
•Analog output signal (0-5V signal).
•Sensor GND (must NOT be connected to engine or chassie ground).
Example 0-5v analog sensor wired to a MaxxECU RACE, see complete PDF wiring diagrams on our download page.
See, connector pinouts.
Example MTune setting for a wired analog 0-5V pressure sensor.
|
Analog filters
Increase the filter value to add filters if the value fluctuates to much. Higher value --> More filter.